Account Contatti
Il tuo carrello
Spedizione DPD & FedEx
Serve aiuto? Chiedi all'AI

APC Rack PDU 2G, Metered by Outlet con switching, ZeroU, 32A, 230V, (21) C13 & (3) C19

APC Rack PDU 2G, Metered by Outlet con switching, ZeroU, 32A, 230V, (21) C13 & (3) C19
APC Rack PDU 2G, Metered by Outlet con switching, ZeroU, 32A, 230V, (21) C13 & (3) C19
APC Rack PDU 2G, Metered by Outlet con switching, ZeroU, 32A, 230V, (21) C13 & (3) C19
APC Rack PDU 2G, Metered by Outlet con switching, ZeroU, 32A, 230V, (21) C13 & (3) C19
APC Rack PDU 2G, Metered by Outlet con switching, ZeroU, 32A, 230V, (21) C13 & (3) C19
APC Rack PDU 2G, Metered by Outlet con switching, ZeroU, 32A, 230V, (21) C13 & (3) C19
APC Rack PDU 2G, Metered by Outlet con switching, ZeroU, 32A, 230V, (21) C13 & (3) C19
APC Rack PDU 2G, Metered by Outlet con switching, ZeroU, 32A, 230V, (21) C13 & (3) C19
2.113,76 €
The APC Switched Rack PDU AP8653 is a 0U rack-mount power distribution unit designed for data center and network cabinets. It provides 24 AC outlets and a fixed 3 m input cable for single-phase power distribution with a nominal input voltage of 230 V and a maximum current rating of 32 A. The unit co... Leggi di più
Stock 78 Codice 2408190 Marca APC Modello AP8653 Garanzia 2 anni

Spedizioni e resi

Consegna stimata Venerdì, Ottobre 16
Ti terremo aggiornato tramite il nostro sistema di tracciamento dettagliato
Opzioni di pagamento
Carta di credito/debitoVisaMastercardPayPalApple PayGoogle PayBonifico bancario

The APC Switched Rack PDU AP8653 is a 0U rack-mount power distribution unit designed for data center and network cabinets. It provides 24 AC outlets and a fixed 3 m input cable for single-phase power distribution with a nominal input voltage of 230 V and a maximum current rating of 32 A. The unit combines switched outlet control and metering capabilities to monitor current, power and voltage at the device level and at individual outlets, and includes temperature/humidity sensor support and locking IEC receptacles for secure connections.

Advantages

The AP8653 offers per-outlet switching and metering so administrators can remotely power on, power off, or recycle individual devices and track real-time load data. Built-in current and power monitoring helps prevent circuit overloads and supports user-defined alarms. The 0U form factor preserves rack space while 24 outlets provide dense power distribution. Certified to EN standards and delivered in a rack-ready configuration with mounting brackets, locking IEC receptacles and configuration accessories, the unit facilitates secure, manageable and auditable power control.

Suitable for

  • Racks and cabinets in data centers and server rooms
  • Network closets and telecom equipment racks
  • Environments requiring remote outlet control and power metering
  • Installations that need sequence-controlled power-up or prioritized load shedding

Key specifications

  • Nominal input voltage: 230 V
  • Maximum current: 32 A
  • AC outlets quantity: 24 outlets
  • PDU type: Switched, Metered
  • Form factor: 0U rack-mount
  • Cable length: 3 m fixed input cable
  • Monitoring: current, power and voltage metering
  • Environmental support: temperature/humidity sensor port
  • Security: locking IEC receptacles
  • Colour: Black
  • Weight: 8.23 kg

How to use

Install the AP8653 in a compatible rack using the supplied mounting brackets in a 0U position to preserve vertical rack space. Connect the 3 m input cable to an appropriate single-phase 230 V supply rated for up to 32 A. Configure network access through the device web interface, SNMP or Telnet, and attach the optional temperature/humidity sensor if environmental monitoring is needed. Use the management interface to set outlet control permissions, power sequencing delays and alarm thresholds, and to view real-time metered values for current, voltage and active power.

Recommendations

To minimize risk of overload, verify total connected load does not exceed the 32 A maximum and use the per-outlet metering to balance loads. Implement access controls and locking IEC cords to prevent unauthorized power changes, and define power-up sequences for dependent equipment to avoid inrush current conflicts during recovery events.

Punti salienti
  • Racks and cabinets in data centers and server rooms
  • Network closets and telecom equipment racks
  • Environments requiring remote outlet control and power metering
  • Installations that need sequence-controlled power-up or prioritized load shedding
  • Nominal input voltage: 230 V
  • Maximum current: 32 A
  • AC outlets quantity: 24 outlets
  • PDU type: Switched, Metered
  • Form factor: 0U rack-mount
  • Cable length: 3 m fixed input cable
  • Monitoring: current, power and voltage metering
  • Environmental support: temperature/humidity sensor port
  • Security: locking IEC receptacles
  • Colour: Black
  • Weight: 8.23 kg
Specifiche
Altezza
1829 mm
Altezza confezione
2038 mm
Altitudine di esercizio
0 - 3000 m
Altitudine non operativa
0 - 15000 m
Capacità di carico
7680 VA
Capacità rack
0U
Certificati di conformità
RoHS
Certificazione
EN 55022 Class A, EN 55024, EN 61000-3-2, EN 61000-3-3, VDE
Colore del prodotto
Black
Controllo delle prese
Lock-out, Recycle, Turn off, Turn on
Corrente massima
32 A
Corrente massima in ingresso per fase
32 A
Corrente massima totale per fase
32 A
Frequenza di ingresso CA
50 - 60 Hz
Funzioni di protezione dell'alimentazione
Overload
Impronta di carbonio totale (kg CO2e)
8595.81
Larghezza
56 mm
Larghezza confezione
162 mm
Lunghezza del cavo
3 m
Monitoraggio
Current, Power, Voltage
Montaggio
Vertical
Numero di prese CA
24 AC outlet(s)
Peso
8.23 kg
Peso confezione
10.5 kg
Potenza massima
7680 W
Profondità
51 mm
Profondità confezione
118 mm
Spina di alimentazione
IEC309
Temperatura di esercizio (T-T)
-5 - 45 °C
Temperatura di stoccaggio (T-T)
-25 - 65 °C
Tensione nominale in ingresso
230 V
Tensione nominale in uscita
230 V
Tipi di PDU
Metered, Metered-by-outlet, Switched
Tipi di prese CA
C13 coupler, C19 coupler
Tipo
Single-phase
Umidità relativa di esercizio (H-H)
5 - 95%
Umidità relativa di stoccaggio (H-H)
5 - 95%
Storico prezzi degli ultimi 6 mesi
APC Rack PDU 2G, Metered by Outlet con switching, ZeroU, 32A, 230V, (21) C13 & (3) C19
Attuale
2.113,76 €
Minimo
2.037,82 €
Massimo
2.228,02 €
Variazione 24 h
+4,99 €   +0%
Settimana
+8,36 €   +0%
Mese
+49,10 €   +2%

Prodotti più popolari in questa categoria

Ciao, sono l'assistente AI di DistriNode. Posso aiutarti a trovare prodotti, confrontare le opzioni, creare preventivi in PDF o aprire richieste di assistenza.