Account Contatti
Il tuo carrello
Spedizione DPD & FedEx
Serve aiuto? Chiedi all'AI

Interruttore intermedio AS Schwabe con PRCD 230 V nero IP55 modello 45223

Interruttore intermedio AS Schwabe con PRCD 230 V nero IP55 modello 45223
Interruttore intermedio AS Schwabe con PRCD 230 V nero IP55 modello 45223
52,23 €
The AS Schwabe Zwischenschalter mit PRCD 230 V Schwarz IP55 Modell 45223 is an inline/intermediate switch with an integrated protective residual current device (PRCD) designed for 230 V circuits. Encased in a black housing with IP55 protection, the unit combines switching functionality and residual ... Leggi di più
Stock 142 Codice 2203646 Marca AS SCHWABE Modello 45223 Garanzia 2 anni

Spedizioni e resi

Consegna stimata Venerdì, Ottobre 23
Ti terremo aggiornato tramite il nostro sistema di tracciamento dettagliato
Opzioni di pagamento
Carta di credito/debitoVisaMastercardPayPalApple PayGoogle PayBonifico bancario

The AS Schwabe Zwischenschalter mit PRCD 230 V Schwarz IP55 Modell 45223 is an inline/intermediate switch with an integrated protective residual current device (PRCD) designed for 230 V circuits. Encased in a black housing with IP55 protection, the unit combines switching functionality and residual current detection to reduce risk from earth faults in temporary power setups, outdoor tools and construction-site equipment. The compact form factor allows insertion into extension leads or fixed cable runs where additional RCD protection is required.

Advantages

The integrated PRCD provides automatic tripping on dangerous leakage currents while the inline switch enables convenient interruption of power without changing the cable layout. The IP55-rated enclosure offers protection against dust ingress and low-pressure water jets, making the device suitable for use in exposed or damp environments. Built for compatibility with standard 230 V supplies, the unit streamlines safety on site by combining two functions in one compact, robust housing.

Suitable for

When it may not be suitable

This inline switch with PRCD is intended for use on single-phase 230 V circuits; it is not suitable for three-phase or high-voltage installations. It is not a substitute for fixed residual-current protection installed in electrical distribution boards for permanent building electrics. For indoor applications that require a flush-mounted or purely aesthetic switch, the rugged IP55 housing may be unnecessarily robust.

Key specifications

How to use

Install the device by cutting the cable at the desired inline point, inserting the conductors into the terminal connections and securing them according to the manufacturer's wiring instructions. Ensure the unit is closed and sealed before use to maintain IP55 protection. Connect to a single-phase 230 V supply and test the PRCD function using the test button after installation and periodically during use. Operate the switch to interrupt power to downstream equipment as required.

What to consider before purchase

Recommendations

Test the PRCD regularly using its built-in test button before each work period or at least weekly in professional environments. Keep the enclosure closed during operation and avoid submersion; while IP55 resists water jets, it is not designed for immersion. Replace the device if it shows signs of damage, heavy wear or if the test or trip functions fail.

Punti salienti
  • Temporary electrical installations on construction sites and renovation works
  • Powering and protecting outdoor electric tools and garden equipment
  • Extension leads and portable cable assemblies used in damp or exposed areas
  • Workshops and maintenance tasks where additional residual-current protection is needed
  • Rated supply voltage: 230 V AC
  • Residual current tripping sensitivity: 30 mA (residual current device)
  • Enclosure protection class: IP55 (dust protected, protected against water jets)
  • Housing color: black
  • Mounting type: inline/intermediate (in-cable) switch
  • Confirm compatibility with your cable type and conductor cross-section for secure terminal connections
  • Ensure a 230 V single-phase supply is used; not suitable for three-phase systems
  • Verify that the 30 mA residual current sensitivity meets local safety requirements for the intended use
  • Consider whether a permanently installed RCD in the distribution board is required in addition to this inline unit
Specifiche
Peso
0.26 kg
Storico prezzi degli ultimi 6 mesi
Interruttore intermedio AS Schwabe con PRCD 230 V nero IP55 modello 45223
Attuale
52,23 €
Minimo
51,50 €
Massimo
62,86 €
Variazione 24 h
+0,61 €   +1%
Settimana
-2,60 €   -5%
Mese
—   

Prodotti più popolari in questa categoria

Ciao, sono l'assistente AI di DistriNode. Posso aiutarti a trovare prodotti, confrontare le opzioni, creare preventivi in PDF o aprire richieste di assistenza.